____________________________________________________________ |
|
To calculate the amount of cable needed, multiply roof edge
length to be heat traced by the spacing factor.
The spacing factor (feet of cable required per foot of roof
edge) is |
| Roof Overhang | Heating Width | Heating Height | Spacing Factor |
| 12" | 2 | 18" | 2 |
| 24" | 2 | 30" | 3 |
| 36" | 2 | 42" | 4 |
Add the total gutter length and the total
downspout length
to the figure calculated above.
|
Also add enough cable to
provide a drip loop prior to going into the box,
Determine how many circuits are required. Divide the total length of cable
Round that number up (for example, 2.1 to 3)to get
the |
Self Regulating Roof and Gutter Heating Cable
120V Or 208 / 277 volt - with braid and weatherproof jacket
Note: Must Be Ordered In 100 ft.
Increments
Or A $25.00 Cutting Charge Is Assessed
|
|
|||||